SWMM 5 Warning Messages
WARNING 01: | wet weather time step reduced to recording interval for Rain Gage xxx. |
The wet weather time step was automatically
reduced so that no period with rainfall would be skipped during a
simulation.
WARNING 02: | maximum depth increased for Node xxx. |
The maximum depth for the node was
automatically increased to match the top of the highest connecting conduit.
WARNING 03: | negative offset ignored for Link xxx. |
The link's stipulated offset was below the
connecting node's invert so its actual offset was set to 0.
WARNING 04: | minimum elevation drop used for Conduit xxx. |
The elevation drop between the end nodes of
the conduit was below 0.001 ft (0.00035 m) so the latter value was used instead
to calculate its slope.
WARNING 05: | minimum slope used for Conduit xxx. |
The conduit's computed slope was below the
user-specified Minimum Conduit Slope
so the latter value was used instead.
WARNING 06: | dry weather time step increased to wet weather time step. |
The user-specified time step for computing
runoff during dry weather periods was lower than that set for wet weather
periods and was automatically increased to the wet weather value.
WARNING 07: | routing time step reduced to wet weather time step. |
The user-specified time step for flow
routing was larger than the wet weather runoff time step and was automatically
reduced to the runoff time step to prevent loss of accuracy.
WARNING 08: | elevation drop exceeds length for Conduit xxx. |
The elevation drop across the ends of a
conduit exceeds its length. The program computes the conduit's slope as the
elevation drop divided by the length instead of using the more accurate right
triangle method. The user should check for errors in the length and in both the
invert elevations and offsets at the conduit's upstream and downstream
nodes.
WARNING 09: | time series interval greater than recording interval for Rain Gage xxx. |
The smallest time interval between entries
in the precipitation time series used by the rain gage is greater than the
recording time interval specified for the gage. If this was not actually
intended then what appear to be continuous periods of rainfall in the time
series will instead be read with time gaps in between them.
WARNING 10: | crest elevation is below downstream invert for regulator Link xxx. |
The height of the opening on an orifice,
weir, or outlet is below the invert elevation of its downstream node. Users
should check to see if the regulator's offset height or the downstream node's
invert elevation is in error.
WARNING 11: | non-matching attributes in Control Rule xxx. |
A control rule's premise is comparing two different types of attributes to one another (for example, conduit flow and junction water depth).